Installing Your Insert Pellet Stove
VENTING INTO AN EXISTING CHIMNEY
53
-RAIN
CAP
f*
INSERT STOVE VENTED INTO
EXISTING CHIMNEY
andlor pipe
support
The Quest insert may be installed in a masonry
or factory built fireplace as shown below. When
I
installing into the existing chimney, the exhaust
venting system should be extended to the top of
the chimney as shown below. However.
If
the
vent pipe is not extended to the top of the
1
chimney, it must extend a minimum of
18
I
1/
,
j
,
inches ahove the chimney damper.
If the
optional horizontal exhaust duct is used, a mini-
mum of 10 ft. of
3
inch vent pipe must be used.
Ensure that the end of any flex pipe used in this
,
.
type of installation is not blocked, when termi-
I!;
I
!I:
nated inside the existing flue.
Note: Any instal-
i
:
I
lation that does not run all the way to the top
11
of the chimney is not recommended.
;:
I
1
I
We also recommend that the fireplace cavity be
thoroughly cleaned and sealed with latex paint or
masonry sealer. The paint will seal in old soot
and creosote and help prevent fine dust from
being pulled into the stove's convection fan and
blown into the house.
IMPORTANT
NOTE:
Make sure the chimney
and
fqlace
are
clean
and
free
of soot and ashes
EEEQ3E
installation
begins. Failure
to
do so
may result in the transfer
i
of soot into the mom.