Mobile Home Installa tion
.
p*.
IN ADDITION TO THE STANDARD
INSTALLATION INSTRUCTIONS, THE
FOLLOWING INSTRUCTIONS MAY BE
REQUIRED
BY
LOCAL, STATE OR FEDERAL
BUILDING CODES:
0
Stove must be permanently bolted to the floor.
Stove must have
a
permanent outside a
Stove must be permanently electrically
chassis of the home.
The
location selected
stove must be dedicated for this purpose.
Refer to page
17
for list of commonly used vent components.
0
NOTE: THE GROUNDING OF THIS PRODUCT, AT INSTALLATION,
MUST COMPLY
WITH NFPA-70 STANDARDS, CSA C22.1 IN CANADA,
AS WELL AS ANY LOCAL CODES.
WARNING:
DO NOT INSTALL IN A SPACE USED AS A BEDROOM.
I I
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED
HOME FLOOR, WALL AND
CEILING/ROOF
MUST BE MAINTAINED.
MOBILE HOME EXHAUST VENT
PIPE
INSTALLATION GUIDELINES
Use only listed type
"L"
pellet vent pipe. Pipe
should extend at least
3
feet above the part of the
roof through which
it
passes. The top of the pipe
should be at least
2
feet above the highest required
elevation of any part of the mobile home within
10
feet of the pipe.
If exhaust vent exits the mobile home at a location
other than the roof, and exits at a point
7
feet or
less above the ground level on which the mobile
home
is
position a guard or method of enclosing
the pipe shall be provided at the point of exit for a
height of up to
7
feet. The openings, if any, in this
guard shall not allow a
314"
rod to pass through.
A
112''
rod could pass through but should not be able
to touch the pipe when inserted through the
opening a distance of
4
inches.
Sfeel Chassis of'
~ledrical Gound Noncombustible
Mobile Home to Chassis
floor Protedion
23